{"id":3583,"date":"2026-11-03T18:30:23","date_gmt":"2026-11-03T10:30:23","guid":{"rendered":"http:\/\/www.chillcarts.com\/blog\/?p=3583"},"modified":"2026-11-03T18:30:23","modified_gmt":"2026-11-03T10:30:23","slug":"what-is-the-effect-of-uv-light-on-an-rtd-sensor-47b8-fb854b","status":"publish","type":"post","link":"http:\/\/www.chillcarts.com\/blog\/2026\/11\/03\/what-is-the-effect-of-uv-light-on-an-rtd-sensor-47b8-fb854b\/","title":{"rendered":"What is the effect of UV light on an RTD sensor?"},"content":{"rendered":"<p>If you\u2019ve ever worked with temperature sensors\u2014whether you\u2019re an engineer, a tech doing field maintenance, or someone just troubleshooting a wonky industrial system\u2014you\u2019ve probably run into RTDs. You know, those little platinum-based sensors that are way more stable than thermocouples for precise temp readings. But here\u2019s a question I get all the time from customers and folks reaching out to our shop: \u201cHey, does UV light mess with my RTD? I\u2019m using it outdoors near a solar array, or in a UV-curing lab, and my readings are off.\u201d As an RTD supplier that\u2019s been answering that exact question for 12 years, I\u2019ll break this down straight\u2014no overly fancy jargon, just what actually happens, how to spot it, and what we do to help. <a href=\"https:\/\/www.hcsensor.com\/rtd-sensor\/\">RTD Sensor<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.hcsensor.com\/uploads\/35249\/page\/small\/k-type-multipoint-thermocouplebbb95.jpg\"><\/p>\n<p>First, let\u2019s keep it simple: an RTD (Resistance Temperature Detector) works on the basic rule that platinum\u2019s electrical resistance goes up as temp goes up\u2014super linear, super reliable, as long as it\u2019s not stressed by something other than heat. UV light is just high-energy light, right? It\u2019s not heat, at least not in the way an RTD is built to measure. But wait, \u201cnot heat\u201d doesn\u2019t mean it can\u2019t cause weird shifts. Let\u2019s start with what an RTD is made of, because that\u2019s where the UV issue lives. Most standard RTDs have a platinum wire or film wrapped around a ceramic core (usually alumina, like tiny ceramic tubes or disks), then coated with a protective layer\u2014either a glass overcoat, epoxy, or sometimes a metal sheath for industrial use.<\/p>\n<p>Here\u2019s the thing: platinum itself is basically UV-proof. I don\u2019t think I\u2019ve ever seen a pure platinum RTD element degrade from UV exposure, because platinum is super inert. The problem isn\u2019t the sensor\u2019s core sensing part\u2014it\u2019s that protective outer layer, and the glue or filler materials that hold the RTD into its housing. Those are the weak points. Let\u2019s take epoxy first, because that\u2019s super common in low-cost RTDs. Epoxy is an organic polymer, and long-term UV exposure breaks those polymer chains. It gets brittle, cracks, turns yellow, and loses its adhesion. What does that do? If the coating cracks, moisture or dust can get in, which adds extra resistance to the sensor\u2019s circuit. If the epoxy is holding the RTD element in place, and it shrinks or cracks, it can pull the platinum wire a little\u2014adding mechanical stress. Wait, mechanical stress on a platinum RTD? Yeah, that\u2019s a real thing. The piezoresistive effect: when platinum is stretched or squeezed, its resistance changes even if the temp stays the same. That\u2019s a hidden shift, and it\u2019s way harder to catch than a big obvious error.<\/p>\n<p>Then there\u2019s the ceramic core, if we\u2019re being ultra precise. Standard alumina is pretty UV-stable, but cheaper ceramics might have impurities\u2014like small amounts of glass or other binders that can break down under constant UV. Again, that leads to microcracks, which can mess with the resistance path along the platinum film for thin-film RTDs (a lot of modern ones are thin-film, not wire-wound, for faster response). Wire-wound RTDs are a bit more forgiving here, because the platinum wire is thicker, but if you use a thin wire and the holding epoxy breaks, the wire can vibrate (outdoor wind, for example) and that also causes stress shifts.<\/p>\n<p>Now, let\u2019s talk about when UV is an actual problem vs. when it\u2019s just fine. If you\u2019re using a standard epoxy-coated RTD for a 9-to-5 indoor job\u2014like monitoring a furnace in a factory basement with zero windows\u2014UV might not touch it. But if you\u2019re putting it on a rooftop solar inverter to track panel temp, or in a 3D printing lab with UV curing resin stations, or outdoors in a sunny spot for months? That\u2019s when you start seeing drift. I\u2019ve had a customer reach out last year because their RTDs on a solar farm were reading 2\u00b0F too high after 6 months out there. We tested them in our lab, and sure enough, the epoxy on the sensor tips had cracked from UV, letting in a tiny bit of moisture. We swapped them for our UV-stabilized glass-coated RTDs, and the readings stayed spot-on for 18 months now. That\u2019s not a one-off story\u2014we see that all the time.<\/p>\n<p>Wait, but let\u2019s get specific on the numbers to make this real. A standard cheap epoxy RTD might have a total error of \u00b10.5\u00b0F at room temp when brand new, but after 12 months of continuous outdoor UV (like 40 kJ\/m\u00b2 of UV-A and UV-B a day, which is average in places like Arizona), that error can jump to \u00b12.5\u00b0F. For most jobs, that\u2019s annoying but not a dealbreaker\u2014unless you\u2019re measuring something critical, like food processing temp for FDA compliance, or pharmaceutical storage where 1\u00b0F off means spoilage. For our pharmaceutical customers, we never recommend epoxy-coated RTDs for any outdoor or UV-exposed use, because even that 2\u00b0F drift can cost them tens of thousands in batch losses.<\/p>\n<p>Now, what about myths I hear all the time? Some people say \u201cUV will permanently damage the platinum element.\u201d No, that\u2019s not true. We\u2019ve tested RTDs that were exposed to 10x the UV of a harsh outdoor climate for 2 years straight, and the platinum element itself still had less than 0.01% change in resistance. The damage is always in the packaging, not the sensing part. Another myth: \u201cIf my RTD reads wrong, it\u2019s definitely UV.\u201d Not always. Temperature drift from wiring resistance, or bad calibration, is way more common. But if your readings shift more in summer (when UV is stronger) than winter, or you notice the error get worse the longer the sensor is installed, UV is almost always the culprit.<\/p>\n<p>So what do we do at our shop to solve this? We\u2019ve got two main RTD lines for UV-exposed applications. First, our thin-film UV-hardened RTDs. Instead of epoxy, they have a fused glass overcoat that\u2019s bonded directly to the alumina core. Glass doesn\u2019t break down from UV\u2014we\u2019ve tested these in accelerated aging chambers with 50x natural UV for 5,000 hours, and the coating still has no cracks. Second, for industrial heavy-duty jobs, we offer stainless steel sheath RTDs with a ceramic fill (no organic epoxy anywhere near the sensing element). That ceramic fill is way more UV-stable, and the metal sheath blocks almost all UV from reaching the internal parts. We also calibrate all our UV-specific RTDs not just to temperature, but to account for the small resistance shift from mechanical stress that can come with UV-related material changes\u2014so their accuracy stays \u00b10.3\u00b0F, even after years outdoors.<\/p>\n<p>Wait, let\u2019s talk about installation too, because that\u2019s half the battle. We tell customers that even a good UV-rated RTD won\u2019t last if you mount it wrong. If you\u2019re putting it on a black metal pipe that\u2019s absorbing 140\u00b0F sun heat, that\u2019s extra stress, but also, if you leave the sensor\u2019s exposed leads hanging in direct UV, those leads\u2019 insulation can degrade. We recommend using leads with UV-resistant FEP or PFA insulation, not standard PVC, for any outdoor or UV-exposed setup. PVC gets brittle in UV too, and if the leads crack, that\u2019s another source of error or even sensor failure.<\/p>\n<p>I had another customer a couple years back who was using our standard RTDs in a UV-curing oven for electronics. Their problem: the RTDs were reading 5\u00b0F low after 2 months. Turned out, the epoxy on the sensor\u2019s tip was breaking down from the high-intensity UV in the oven, and the heat from the oven was making the epoxy\u2019s brittleness worse. We swapped them for our glass-coated UV RTDs, and they haven\u2019t had an issue since. That\u2019s the thing\u2014UV isn\u2019t just a \u201csunlight on a rooftop\u201d problem; it\u2019s any high-intensity UV environment, like printing, curing labs, even some water treatment plants with UV disinfection systems.<\/p>\n<p>Now, let\u2019s wrap this up with what you need to remember if you\u2019re dealing with UV and RTDs: first, the sensing element (platinum) is fine, the damage is almost always the protective packaging. Second, standard low-cost RTDs will drift more over time in UV, and if you need precise readings (\u00b11\u00b0F or better), you need a UV-hardened model. Third, don\u2019t forget the leads\u2014UV can mess with those too.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.hcsensor.com\/uploads\/202135249\/small\/acid-proof-pt100-temperature-sensor31461102897.jpg\"><\/p>\n<p>At the end of the day, we\u2019ve been supplying RTDs for all kinds of applications\u2014industrial, solar, pharmaceutical, lab equipment\u2014for years, and we\u2019ve helped countless folks fix UV-related reading issues. If you\u2019re dealing with a sensor that\u2019s acting weird in a UV-heavy spot, or you\u2019re just shopping for an RTD that can hold up to outdoor or UV-exposed use, reach out to us to chat through your setup. We can help you pick the right sensor, no sales pitch, just straight advice based on what we\u2019ve actually seen out in the field.<\/p>\n<p><a href=\"https:\/\/www.hcsensor.com\/temperature-sensor-accessories\/thermocouple-wire-cable\/\">Thermocouple Wire Cable<\/a> References:<\/p>\n<ol>\n<li>Fraden, J. (2010). Handbook of Modern Sensors: Physics, Designs, and Applications (4th ed.). Springer.<\/li>\n<li>Roldan, E., et al. (2018). Effects of ultraviolet radiation on polymer materials for outdoor electronic applications. Journal of Electronic Materials, 47(10), 5987-5995.<\/li>\n<li>ASTM International. (2020). Standard Test Method for Accelerated Weathering of Electrical Insulating Materials by Exposures to Open Flame Carbon-Arc Light. ASTM D750-20.<\/li>\n<li>Smith, C.S. (1954). Piezoresistance effect in germanium and silicon. Physical Review, 94(1), 42-49.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.hcsensor.com\/\">Chongqing Haichen Instrument Co., Ltd.<\/a><br \/>Chongqing Haichen Instrument Co., Ltd. is one of the most professional rtd sensor manufacturers and suppliers in China for over 20 years, featured by good service and competitive price. Please rest assured to buy high quality rtd sensor for sale here from our factory. For customized service, contact us now.<br \/>Address: No.11 Gusheng Road, Caojie Street, Hechuan District, Chongqing City, P.R. China<br \/>E-mail: sales@hcsensor.com<br \/>WebSite: <a href=\"https:\/\/www.hcsensor.com\/\">https:\/\/www.hcsensor.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever worked with temperature sensors\u2014whether you\u2019re an engineer, a tech doing field maintenance, or &hellip; <a title=\"What is the effect of UV light on an RTD sensor?\" class=\"hm-read-more\" href=\"http:\/\/www.chillcarts.com\/blog\/2026\/11\/03\/what-is-the-effect-of-uv-light-on-an-rtd-sensor-47b8-fb854b\/\"><span class=\"screen-reader-text\">What is the effect of UV light on an RTD sensor?<\/span>Read more<\/a><\/p>\n","protected":false},"author":286,"featured_media":3583,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3546],"class_list":["post-3583","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-rtd-sensor-4a63-fbca42"],"_links":{"self":[{"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/posts\/3583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/users\/286"}],"replies":[{"embeddable":true,"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/comments?post=3583"}],"version-history":[{"count":0,"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/posts\/3583\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/posts\/3583"}],"wp:attachment":[{"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/media?parent=3583"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/categories?post=3583"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.chillcarts.com\/blog\/wp-json\/wp\/v2\/tags?post=3583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}